Econergy HP4000LT Heat Pump Water Heater

$4,343.48 excl. GST

  • Econergy’s main heat pump water heater, made in Auckland
  • 3.5 kW output, suits households of 2 to 8 people
  • Connects to your existing hot water cylinder or an Econergy heat pump-ready cylinder
  • Econergy’s tested figure: 73.8% annual energy savings in the North Island

The HP4000LT heats your water with energy from the air, so it uses far less electricity than an electric element. We supply, install and service it across Rodney and North Auckland. Call us on 0800 278 296 for a free site visit and quote.

SKU: ECO - HP4000LT Categories: , Brand:

A split heat pump that works with your cylinder

The HP4000LT is a split system: the heat pump unit connects to your hot water cylinder with insulated pipes and cables, up to 9 metres apart. It can work with your existing cylinder or with an Econergy heat pump-ready cylinder. We check your cylinder is suitable at the site visit.

How much it saves

Econergy’s tested figure for the HP4000LT is 73.8% less energy a year than an electric hot water cylinder in Zone 5 (the North Island, except the Taupō area), and 71.1% in Zone 6, tested to AS/NZS 4234 and AS/NZS 5125. Your actual savings depend on how much hot water you use and your power prices.

Guarantee and warranty

For a single family home, Econergy gives a six-year performance guarantee of at least 66% savings compared with a standard electric hot water cylinder, alongside a six-year parts warranty and three years’ labour, when the system is installed and certified to Econergy’s installation manual. The warranty doesn’t cover damage from hard or corrosive water, so we check your water first: see how your water affects your hot water cylinder.

Winter and tank water

Econergy rates the HP4000LT for air temperatures from -5°C to 40°C, and the electric element takes over if it stays colder than about -4°C. It needs at least 50 kPa of water pressure, so it suits tank water with the right pump.

Compare the range on our Econergy heat pump page, or see all our heat pump water heaters. Call us on 0800 278 296 for a free site visit and quote.

Specifications

Econergy HP4000LT heat pump water heater

Model HP4000LT heat pump water heater
Household size 2-8 person household
Rated heat output 3.5 kW
Efficiency (COP) 3.8
Min Water Pressure 50kPa
Minimum HP operating temperature -4°C
Dimensions 520mm H x 490mm W x 550mm D
Weight 50kg
Water inlet/outlet RP ½”/15mm
Noise rating 52dBa @ 1.5m
Electrical Connection 10A/ 230V

Compare Models

Compare the Econergy range

Model Type Heat output Heats about Efficiency (COP)
HP4000LT Split, connects to a cylinder 3.5 kW 67 litres an hour 3.8
THD3500 Split, connects to a cylinder, solar mode 3.0 kW 57 litres an hour 3.22
Thermoplus TH-260D1 All-in-one with a 260 litre cylinder 2.9 kW Not stated 4.4 (EN16147)

Figures are from the manufacturer’s brochures. The efficiency figures come from different test standards, so they aren’t directly comparable. Econergy’s tested figure for the HP4000LT is 73.8% annual energy savings compared with an electric hot water cylinder in the North Island. We’ll recommend the right model for your household at a free site visit.

Download Documents

Econergy HP4000LT User Manual 2022

Econergy User Manual 2022

Econergy Parts and Labour Warranty

Econergy Parts & Labour Warranty